Fracture resistance of endodontically treated teeth using fiber post with an elastic modulus similar to dentin
Pornpot JIANGKONGKHOKrid KAMONKHANTIKULHidekazu TAKAHASHIMansuang ARKSORNNUKIT
Author information
JOURNAL FREE ACCESS

2013 Volume 32 Issue 5 Pages 781-786

Details
Abstract

This study investigated the effect of fiber reinforced composite resin (FRC) post lengths, ferrule, and full coverage metal crown onfracture resistance of endodontically treated teeth (ETT) using an experimental FRC post with the similar elastic modulus of dentin (11.5 GPa). ETT was restored according to 1 of 7 combinations of FRC post length (10, 5, 2.5, 0 mm), ferrule (0, 2 mm), and with/without metal crown (n=6). An oblique compressive load was applied on the restored teeth using a universal testing machine. Fracture loads were evaluated with 1-way ANOVA and Tukey HSD test (p<0.05). Compared with tooth preparation only, the fracture loads of ETT restored with composite resin and different post lengths were not significantly different. The group with the ferrule with metal crown showed significantly greater fracture resistance than the others.

Content from these authors
© 2013 The Japanese Society for Dental Materials and Devices