2000 年 63 巻 2 号 p. 73-78
Changes in blood lactic acid density after 10 minutes of 80% VO2max. bicycle exercise due to bathing in CO2 water obtained from a newly developed CO2 water generator (MCH-C80: Maeda Iron Works Co., Ltd.) were compared with changes due to bathing in plain water. The blood lactic acid density increased from 1.6mmol/l to 9.3mmol/l due to the exercise load, but decreased to 3.3mmol/l after 10 minutes of CO2 water bathing at 38°C and further decreased to 1.9mmol/l after 30 minutes. In the group bathing in plain water, blood lactic acid density decreased to 4.0mmol/l immediately after bathing and to 2.3mmol/l after 30 minutes. The difference in results between the CO2 water bathing group and plain water groups was significant (p<0.05). No bad effects of CO2 water bathing were observed. Thus, CO2 water obtained from this CO2 water obtained from this CO2 water generator is useful for enhancing the effect of bathing on recovery from fatigue.