2002 Volume 2 Issue 4 Pages 294-296
For almost all optical disks, signal decline is mainly due to inter symbol interference (ISI) caused by laser beam spot size or magnetic aperture size. Such 151 does not appear for Zero Field Magnetic Amplifying Magneto-optical System (Zero Field MAMMOS). The limit of the frequency response comes from the frequency range of the MO readout channel. MAMMOS has a resolution for 1/10 of a laser beam corresponding to 0.1μm. Decrease in the carrier level and error of less than 0.1μm is caused by expansion failure. If expansion failure were circumvented, Zero Field MAMMOS would have a possibility of readout with 0.04μm resolution using a laser with wavelength, 650nm and an objective lens of NA, 0.6.