Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Effects of chlorhexidine in self-etching adhesive: 24 hours results
Yoshihiro NISHITANIKeiichi HOSAKATomohiro HOSHIKAMasahiro YOSHIYAMADavid H. PASHLEY
Author information
JOURNAL FREE ACCESS

2013 Volume 32 Issue 3 Pages 420-424

Details
Abstract

It is known that chlorhexidine (CHX) does not inhibit micro-tensile bond strengths (MTBS) when it is used in etch-and-rinse adhesives. In that technique, CHX is applied to dentin as a primer after phosphoric acid-etching before bonding with Single Bond. It would be more convenient if it is possible to incorporate CHX into the adhesive. The purpose of this study was to compare the MTBS and the FT-IR percent conversion of an all-in-one self-etching adhesives contained varying concentration of CHX. Extracted human third molars were bonded with a control all-in-one adhesive or experimental versions containing 0.5, 1, 2 or 5% CHX. The MTBS and the percent conversion of experimental adhesives containing up to 1% CHX were not significantly CHX-free control adhesives. However, addition of 2 or especially 5% CHX experimental adhesives produced significant reductions in both the MTBS and the percent conversion.

Content from these authors
© 2013 The Japanese Society for Dental Materials and Devices